Figure 2
PUSH DOWN
TO LOCK
PRY OUT
TO UNLOCK
VERIFY GASKET IS
SEATED IN FEMALE
END OF PIPE
MALE
END
FEMALE
END
Figure 3
APPLIANCE CONNECTION: 2" - 4"
1. If the appliance has a PVC/CPVC female
outlet use the Appliance Adapter/ PVC
Adapter and Clamp. (Fig.4)
• If the appliance has a PVC/CPVC
Male outlet use a matching PVC/
CPVC coupling to convert to a
female outlet.
2. If the appliance outlet has a rubber
boot or Fernco-style appliance adapter,
then the PolyPro vent pipe may attach
directly to the appliance (Fig.5).
3. If the appliance has a FasNSeal outlet
then use the FasNSeal to PolyPro
adapter.
6
Figure 5
APPLIANCE
OUTLET
POLYPRO
VENT PIPE
TIGHTEN CLAMPS ON
RUBBER COUPLER
ADAPTER OR FERNCO
STYLE ADAPTER TO
SECURE VENT
PIPE TO APPLIANCE
Figure 4
POLYPRO PIPE
APPLIANCE
ADAPTER CLAMP
APPLIANCE
ADAPTER/PVC
ADAPTER
APPLIANCE
EXHAUST
OUTLET OR
PVC UNION
APPLIANCE
PROJECTION
ADAPTER
LOCKING
BAND
Connecting DuraVent's metal 1738/S636
system to a PolyPro system (Fig.3)
1. Slide locking band onto appropriate
adapter
• Align slot on locking band with
projection on adapter
• Slide locking band past projection
• Rotate Locking Band above
projection so locking mechanism is
opposite projection
2. Slide adapter into PolyPro pipe
3. Lock Locking band to PolyPro
• Ensure locking band is above
projection on pipe
LOCKING BAND